Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Audiol ; 60(5): 374-384, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33074733

RESUMO

OBJECTIVE: Despite the positive effect of a cochlear implant (CI) on tinnitus in many patients, tinnitus remains a problem for a significant proportion of CI users. We investigated the acceptability and effect of sound therapy (a combination of natural background sounds and one concise tinnitus counselling session) on tinnitus and speech perception in CI users who still experienced tinnitus during CI use. DESIGN AND STUDY SAMPLE: Thirty-two CI users (32-78 years) participated in phase 1: a test at the clinic to evaluate six background sounds provided by the sound processor. Eighteen out of the 32 CI users participated in phase 2: an optional take-home evaluation of 2 weeks without sound therapy, followed by 5 weeks with sound therapy, ending with an evaluation visit. RESULTS: Thirty subjects (93.8%) found at least one background sound acceptable. In phase 2, a small improvement with sound therapy was found for tinnitus loudness, annoyance, and intrusiveness. 50% of the subjects subjectively reported benefit of sound therapy. Especially the sense of control on their tinnitus was highly appreciated. No detrimental effect on speech perception was observed. CONCLUSION: The background sounds were acceptable and provided tinnitus relief in some CI users with tinnitus during CI use.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Zumbido , Humanos , Som , Zumbido/diagnóstico , Zumbido/terapia
2.
Int J Audiol ; 49(9): 657-66, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20583945

RESUMO

Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rates tended to give lower scores. However, there were no significant differences between the word scores across subjects if collected at the individually preferred pulse rate. High pulse rates were preferred when the post-implantation threshold was low.


Assuntos
Percepção Auditiva , Implantes Cocleares , Correção de Deficiência Auditiva , Perda Auditiva Neurossensorial/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Processamento de Sinais Assistido por Computador , Percepção da Fala , Estimulação Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria da Fala , Limiar Auditivo , Estimulação Elétrica , Europa (Continente) , Perda Auditiva Neurossensorial/psicologia , Humanos , Percepção Sonora , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Ajuste de Prótese , Índice de Gravidade de Doença , Adulto Jovem
3.
Int J Audiol ; 43 Suppl 1: S10-5, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15732376

RESUMO

The purpose of this study was to evaluate the performance of the new features of the Nucleus Research Platform 8 (RP8), a system developed specifically for research purposes The RP8 consists of a research implant, a speech processor and a new NRT software (NRT v4), and includes comparisons of the different artefact-cancellation methods, NRT threshold, and recovery function measurements. The system has new artefact-suppression techniques and new diagnostic capabilities; their performance has been verified in animal experiments. In this study, NRT data were collected from 15 postlingually deafened adult cochlear implant patients intraoperatively and up to 6 months postoperatively after switch-on. The initial investigation in two clinics in Europe focused primarily on the enhanced NRT capabilities Results from the trial in two European clinics indicate that NRT measurements can be obtained with lower noise levels. A comparison of the different artefact-cancellation techniques showed that the forward-masking paradigm implemented in the Nucleus 3 system is still the method of choice. The focus of this report is on recovery function characteristics, which may give insight into auditory nerve fiber properties with regard to higher stimulation rates.


Assuntos
Implante Coclear , Implantes Cocleares , Nervo Coclear/fisiologia , Potenciais Evocados Auditivos/fisiologia , Testes Auditivos/métodos , Telemetria/instrumentação , Adolescente , Adulto , Eletrodos , Humanos , Monitorização Intraoperatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...